1Kernel driver max34440 2====================== 3 4Supported chips: 5 * Maxim MAX34440 6 Prefixes: 'max34440' 7 Addresses scanned: - 8 Datasheet: http://datasheets.maxim-ic.com/en/ds/MAX34440.pdf 9 * Maxim MAX34441 10 PMBus 5-Channel Power-Supply Manager and Intelligent Fan Controller 11 Prefixes: 'max34441' 12 Addresses scanned: - 13 Datasheet: http://datasheets.maxim-ic.com/en/ds/MAX34441.pdf 14 15Author: Guenter Roeck <guenter.roeck@ericsson.com> 16 17 18Description 19----------- 20 21This driver supports hardware montoring for Maxim MAX34440 PMBus 6-Channel 22Power-Supply Manager and MAX34441 PMBus 5-Channel Power-Supply Manager 23and Intelligent Fan Controller. 24 25The driver is a client driver to the core PMBus driver. Please see 26Documentation/hwmon/pmbus for details on PMBus client drivers. 27 28 29Usage Notes 30----------- 31 32This driver does not auto-detect devices. You will have to instantiate the 33devices explicitly. Please see Documentation/i2c/instantiating-devices for 34details. 35 36 37Platform data support 38--------------------- 39 40The driver supports standard PMBus driver platform data. 41 42 43Sysfs entries 44------------- 45 46The following attributes are supported. Limits are read-write; all other 47attributes are read-only. 48 49in[1-6]_label "vout[1-6]". 50in[1-6]_input Measured voltage. From READ_VOUT register. 51in[1-6]_min Minumum Voltage. From VOUT_UV_WARN_LIMIT register. 52in[1-6]_max Maximum voltage. From VOUT_OV_WARN_LIMIT register. 53in[1-6]_lcrit Critical minumum Voltage. VOUT_UV_FAULT_LIMIT register. 54in[1-6]_crit Critical maximum voltage. From VOUT_OV_FAULT_LIMIT register. 55in[1-6]_min_alarm Voltage low alarm. From VOLTAGE_UV_WARNING status. 56in[1-6]_max_alarm Voltage high alarm. From VOLTAGE_OV_WARNING status. 57in[1-6]_lcrit_alarm Voltage critical low alarm. From VOLTAGE_UV_FAULT status. 58in[1-6]_crit_alarm Voltage critical high alarm. From VOLTAGE_OV_FAULT status. 59in[1-6]_highest Historical maximum voltage. 60in[1-6]_reset_history Write any value to reset history. 61 62curr[1-6]_label "iout[1-6]". 63curr[1-6]_input Measured current. From READ_IOUT register. 64curr[1-6]_max Maximum current. From IOUT_OC_WARN_LIMIT register. 65curr[1-6]_crit Critical maximum current. From IOUT_OC_FAULT_LIMIT register. 66curr[1-6]_max_alarm Current high alarm. From IOUT_OC_WARNING status. 67curr[1-6]_crit_alarm Current critical high alarm. From IOUT_OC_FAULT status. 68curr[1-6]_highest Historical maximum current. 69curr[1-6]_reset_history Write any value to reset history. 70 71 in6 and curr6 attributes only exist for MAX34440. 72 73temp[1-8]_input Measured temperatures. From READ_TEMPERATURE_1 register. 74 temp1 is the chip's internal temperature. temp2..temp5 75 are remote I2C temperature sensors. For MAX34441, temp6 76 is a remote thermal-diode sensor. For MAX34440, temp6..8 77 are remote I2C temperature sensors. 78temp[1-8]_max Maximum temperature. From OT_WARN_LIMIT register. 79temp[1-8]_crit Critical high temperature. From OT_FAULT_LIMIT register. 80temp[1-8]_max_alarm Temperature high alarm. 81temp[1-8]_crit_alarm Temperature critical high alarm. 82temp[1-8]_highest Historical maximum temperature. 83temp[1-8]_reset_history Write any value to reset history. 84 85 temp7 and temp8 attributes only exist for MAX34440. 86