xref: /cloud-hypervisor/docs/hotplug.md (revision fee769bed4c58a07b67e25a7339cfd397f701f3a)
1# Cloud Hypervisor Hot Plug
2
3Currently Cloud Hypervisor supports hot plugging of CPUs devices (x86 only), PCI devices and memory resizing.
4
5## Kernel support
6
7For hotplug on Cloud Hypervisor ACPI GED support is needed. This can either be achieved by turning on `CONFIG_ACPI_REDUCED_HARDWARE_ONLY`
8or by using this kernel patch (available in 5.5-rc1 and later): https://git.kernel.org/pub/scm/linux/kernel/git/torvalds/linux.git/patch/drivers/acpi/Makefile?id=ac36d37e943635fc072e9d4f47e40a48fbcdb3f0
9
10## CPU Hot Plug
11
12Extra vCPUs can be added and removed from a running `cloud-hypervisor` instance. This is controlled by two mechanisms:
13
141. Specifying a number of maximum potential vCPUs that is greater than the number of default (boot) vCPUs.
152. Making a HTTP API request to the VMM to ask for the additional vCPUs to be added.
16
17To use CPU hotplug start the VM with the number of max vCPUs greater than the number of boot vCPUs, e.g.
18
19```shell
20$ pushd $CLOUDH
21$ sudo setcap cap_net_admin+ep ./cloud-hypervisor/target/release/cloud-hypervisor
22$ ./cloud-hypervisor/target/release/cloud-hypervisor \
23	--kernel custom-vmlinux.bin \
24	--cmdline "console=ttyS0 console=hvc0 root=/dev/vda1 rw" \
25	--disk path=focal-server-cloudimg-amd64.raw \
26	--cpus boot=4,max=8 \
27	--memory size=1024M \
28	--net "tap=,mac=,ip=,mask=" \
29	--rng \
30	--api-socket=/tmp/ch-socket
31$ popd
32```
33
34Notice the addition of `--api-socket=/tmp/ch-socket` and a `max` parameter on `--cpus boot=4,max=8`.
35
36To ask the VMM to add additional vCPUs then use the resize API:
37
38```shell
39./ch-remote --api-socket=/tmp/ch-socket resize --cpus 8
40```
41
42The extra vCPU threads will be created and advertised to the running kernel. The kernel does not bring up the CPUs immediately and instead the user must "online" them from inside the VM:
43
44```shell
45root@ch-guest ~ # lscpu | grep list:
46On-line CPU(s) list:             0-3
47Off-line CPU(s) list:            4-7
48root@ch-guest ~ # echo 1 | tee /sys/devices/system/cpu/cpu[4,5,6,7]/online
491
50root@ch-guest ~ # lscpu | grep list:
51On-line CPU(s) list:             0-7
52```
53
54After a reboot the added CPUs will remain.
55
56Removing CPUs works similarly by reducing the number in the "desired_vcpus" field of the resize API. The CPUs will be automatically offlined inside the guest so there is no need to run any commands inside the guest:
57
58```shell
59./ch-remote --api-socket=/tmp/ch-socket resize --cpus 2
60```
61
62As per adding CPUs to the guest, after a reboot the VM will be running with the reduced number of vCPUs.
63
64## Memory Hot Plug
65
66### ACPI method
67
68Extra memory can be added from a running `cloud-hypervisor` instance. This is controlled by two mechanisms:
69
701. Allocating some of the guest physical address space for hotplug memory.
712. Making a HTTP API request to the VMM to ask for a new amount of RAM to be assigned to the VM. In the case of expanding the memory for the VM the new memory will be hotplugged into the running VM, if reducing the size of the memory then change will take effect after the next reboot.
72
73To use memory hotplug start the VM specifying some size RAM in the `hotplug_size` parameter to the memory configuration. Not all the memory specified in this parameter will be available to hotplug as there are spacing and alignment requirements so it is recommended to make it larger than the hotplug RAM needed.
74
75Because the ACPI method is the default, there is no need to add the extra option `hotplug_method=acpi`.
76
77```shell
78$ pushd $CLOUDH
79$ sudo setcap cap_net_admin+ep ./cloud-hypervisor/target/release/cloud-hypervisor
80$ ./cloud-hypervisor/target/release/cloud-hypervisor \
81	--kernel custom-vmlinux.bin \
82	--cmdline "console=ttyS0 console=hvc0 root=/dev/vda1 rw" \
83	--disk path=focal-server-cloudimg-amd64.raw \
84	--cpus boot=4,max=8 \
85	--memory size=1024M,hotplug_size=8192M \
86	--net "tap=,mac=,ip=,mask=" \
87	--rng \
88	--api-socket=/tmp/ch-socket
89$ popd
90```
91
92Before issuing the API request it is necessary to run the following command inside the VM to make it automatically online the added memory:
93
94```shell
95root@ch-guest ~ # echo online | sudo tee /sys/devices/system/memory/auto_online_blocks
96```
97
98To ask the VMM to expand the RAM for the VM:
99
100```shell
101./ch-remote --api-socket=/tmp/ch-socket resize --memory 3G
102```
103
104The new memory is now available to use inside the VM:
105
106```shell
107free -h
108              total        used        free      shared  buff/cache   available
109Mem:          3.0Gi        71Mi       2.8Gi       0.0Ki        47Mi       2.8Gi
110Swap:          32Mi          0B        32Mi
111```
112
113Due to guest OS limitations is is necessary to ensure that amount of memory added (between currently assigned RAM and that which is desired) is a multiple of 128MiB.
114
115The same API can also be used to reduce the desired RAM for a VM but the change will not be applied until the VM is rebooted.
116
117Memory and CPU resizing can be combined together into the same HTTP API request.
118
119### virtio-mem method
120
121Extra memory can be added and removed from a running Cloud Hypervisor instance. This is controlled by two mechanisms:
122
1231. Allocating some of the guest physical address space for hotplug memory.
1242. Making a HTTP API request to the VMM to ask for a new amount of RAM to be assigned to the VM.
125
126To use memory hotplug start the VM specifying some size RAM in the `hotplug_size` parameter along with `hotplug_method=virtio-mem` to the memory configuration.
127
128```shell
129$ pushd $CLOUDH
130$ sudo setcap cap_net_admin+ep ./cloud-hypervisor/target/release/cloud-hypervisor
131$ ./cloud-hypervisor/target/release/cloud-hypervisor \
132	--kernel custom-vmlinux.bin \
133	--cmdline "console=ttyS0 console=hvc0 root=/dev/vda1 rw" \
134	--disk path=focal-server-cloudimg-amd64.raw \
135	--memory size=1024M,hotplug_size=8192M,hotplug_method=virtio-mem \
136	--net "tap=,mac=,ip=,mask=" \
137	--api-socket=/tmp/ch-socket
138$ popd
139```
140
141To ask the VMM to expand the RAM for the VM (request is in bytes):
142
143```shell
144./ch-remote --api-socket=/tmp/ch-socket resize --memory 3G
145```
146
147The new memory is now available to use inside the VM:
148
149```shell
150free -h
151              total        used        free      shared  buff/cache   available
152Mem:          3.0Gi        71Mi       2.8Gi       0.0Ki        47Mi       2.8Gi
153Swap:          32Mi          0B        32Mi
154```
155
156The same API can also be used to reduce the desired RAM for a VM. It is important to note that reducing RAM size might only partially work, as the guest might be using some of it.
157
158## PCI Device Hot Plug
159
160Extra PCI devices can be added and removed from a running `cloud-hypervisor` instance. This is controlled by making a HTTP API request to the VMM to ask for the additional device to be added, or for the existing device to be removed.
161
162Note: On AArch64 platform, PCI device hotplug can only be achieved using ACPI. Please refer to the [documentation](uefi.md#building-uefi-firmware-for-aarch64) for more information.
163
164To use PCI device hotplug start the VM with the HTTP server.
165
166```shell
167$ sudo setcap cap_net_admin+ep ./cloud-hypervisor/target/release/cloud-hypervisor
168$ ./cloud-hypervisor/target/release/cloud-hypervisor \
169	--kernel custom-vmlinux.bin \
170	--cmdline "console=ttyS0 console=hvc0 root=/dev/vda1 rw" \
171	--disk path=focal-server-cloudimg-amd64.raw \
172	--cpus boot=4 \
173	--memory size=1024M \
174	--net "tap=,mac=,ip=,mask=" \
175	--api-socket=/tmp/ch-socket
176```
177
178Notice the addition of `--api-socket=/tmp/ch-socket`.
179
180### Add VFIO Device
181
182To ask the VMM to add additional VFIO device then use the `add-device` API.
183
184```shell
185./ch-remote --api-socket=/tmp/ch-socket add-device path=/sys/bus/pci/devices/0000:01:00.0/
186```
187
188### Add Disk Device
189
190To ask the VMM to add additional disk device then use the `add-disk` API.
191
192```shell
193./ch-remote --api-socket=/tmp/ch-socket add-disk path=/foo/bar/cloud.img
194```
195
196### Add Fs Device
197
198To ask the VMM to add additional fs device then use the `add-fs` API.
199
200```shell
201./ch-remote --api-socket=/tmp/ch-socket add-fs tag=myfs,socket=/foo/bar/virtiofs.sock
202```
203
204### Add Net Device
205
206To ask the VMM to add additional network device then use the `add-net` API.
207
208```shell
209./ch-remote --api-socket=/tmp/ch-socket add-net tap=chtap0
210```
211
212### Add Pmem Device
213
214To ask the VMM to add additional PMEM device then use the `add-pmem` API.
215
216```shell
217./ch-remote --api-socket=/tmp/ch-socket add-pmem file=/foo/bar.cloud.img
218```
219
220### Add Vsock Device
221
222To ask the VMM to add additional vsock device then use the `add-vsock` API.
223
224```shell
225./ch-remote --api-socket=/tmp/ch-socket add-vsock cid=3,socket=/foo/bar/vsock.sock
226```
227
228### Common Across All PCI Devices
229
230The extra PCI device will be created and advertised to the running kernel. The new device can be found by checking the list of PCI devices.
231
232```shell
233root@ch-guest ~ # lspci
23400:00.0 Host bridge: Intel Corporation Device 0d57
23500:01.0 Unassigned class [ffff]: Red Hat, Inc. Virtio console (rev 01)
23600:02.0 Mass storage controller: Red Hat, Inc. Virtio block device (rev 01)
23700:03.0 Unassigned class [ffff]: Red Hat, Inc. Virtio RNG (rev 01)
238```
239
240After a reboot the added PCI device will remain.
241
242### Remove PCI device
243
244Removing a PCI device works the same way for all kind of PCI devices. The unique identifier related to the device must be provided. This identifier can be provided by the user when adding the new device, or by default Cloud Hypervisor will assign one.
245
246```shell
247./ch-remote --api-socket=/tmp/ch-socket remove-device _disk0
248```
249
250As per adding a PCI device to the guest, after a reboot the VM will be running without the removed PCI device.