Lines Matching full:maintenance

360  * @charge_current_max_ua: maintenance charging current that is used to keep
363 * reach this voltage the maintenance charging current is turned off. It is
365 * @charge_voltage_max_uv: maintenance charging voltage that is usually a bit
368 * @safety_timer_minutes: maintenance charging safety timer, with an expiry
369 * time in minutes. We will only use maintenance charging in this setting
371 * maintenance charge current and voltage pair in respective array and wait
396 * To prolong the life of the battery, maintenance charging is applied after
407 * Maintenance charging uses the voltages from this table: a table of settings
409 * CC/CV charging. The maintenance charging will for safety reasons not go on
410 * indefinately: we lower the current and voltage with successive maintenance
417 * at 900mA to 4340mV, then maintenance charged at 600mA and 4150mV for up to
418 * 60 hours, then maintenance charged at 600mA and 4100mV for up to 200 hours.
422 * For most mobile electronics this type of maintenance charging is enough for
423 * the user to disconnect the device and make use of it before both maintenance
428 * If the voltage anyway drops to charge_restart_voltage_uv during maintenance
468 * poles reach charge_restart_voltage_uv unless we use maintenance charging.
485 * @maintenance_charge: an array of maintenance charging settings to be used
487 * @maintenance_charge_size: the number of maintenance charging settings in
650 * After this the battery is fully charged, and if we do not support maintenance
656 * If we support maintenance charging the voltage is however kept high after