Lines Matching +full:system +full:- +full:critical +full:- +full:regulator
15 device within the system.
16 The contents of the label are free-form.
40 Voltage critical min value.
46 If voltage drops to or below this limit, the system may
60 Voltage critical max value.
66 If voltage reaches or exceeds this limit, the system may
135 this voltage channel is being used for, and user-space
137 user-space.
145 When disabled the sensor read will return -ENODATA.
147 - 1: Enable
148 - 0: Disable
164 Voltage Regulator Module version number.
253 Only makes sense if the chip supports closed-loop fan speed
263 this fan channel is being used for, and user-space doesn't.
264 In all other cases, the label is provided by user-space.
272 When disabled the sensor read will return -ENODATA.
274 - 1: Enable
275 - 0: Disable
283 - 1: Failed
284 - 0: Ok
302 - 0: no fan speed control (i.e. fan at full speed)
303 - 1: manual fan speed control enabled (using `pwmY`)
304 - 2+: automatic fan speed control enabled
313 - 0: DC mode (direct current)
314 - 1: PWM mode (pulse-width modulation)
343 Number of trip points is chip-dependent. Use this for chips
354 Number of trip points is chip-dependent. Use this for chips
367 - 1: CPU embedded diode
368 - 2: 3904 transistor
369 - 3: thermal diode
370 - 4: thermistor
371 - 5: AMD AMDSI
372 - 6: Intel PECI
388 - 0: OK
389 - 1: temperature has reached tempY_max
405 - 0: OK
406 - 1: temperature has reached tempY_min
441 Temperature critical max value, typically greater than
450 Critical high temperature alarm flag.
452 - 0: OK
453 - 1: temperature has reached tempY_crit
459 Temperature hysteresis value for critical limit.
464 from the critical value.
482 - 0: OK
483 - 1: temperature has reached tempY_emergency
500 Temperature critical min value, typically lower than
509 Temperature hysteresis value for critical min limit.
514 from the critical min value.
534 this temperature channel is being used for, and user-space
536 user-space.
572 When disabled the sensor read will return -ENODATA.
574 - 1: Enable
575 - 0: Disable
613 Current critical low value
621 Current critical high value.
673 When disabled the sensor read will return -ENODATA.
675 - 1: Enable
676 - 0: Disable
808 system should take action to reduce power use.
853 Critical maximum power.
856 system is expected take drastic action to reduce
857 power consumption, such as a system shutdown or
869 -ENODATA.
871 - 1: Enable
872 - 0: Disable
905 -ENODATA.
907 - 1: Enable
908 - 0: Disable
916 - 0: OK
917 - 1: Humidity limit has been reached
926 -ENODATA.
928 - 1: Enable
929 - 0: Disable
937 - 1: Failed
938 - 0: Ok
946 Unit: milli-percent (per cent mille, pcm)
957 this humidity channel is being used for, and user-space
959 user-space.
967 Unit: milli-percent (per cent mille, pcm)
975 Unit: milli-percent (per cent mille, pcm)
986 Unit: milli-percent (per cent mille, pcm)
994 Unit: milli-percent (per cent mille, pcm)
1005 Unit: milli-percent (per cent mille, pcm)
1013 Unit: milli-percent (per cent mille, pcm)
1022 - 0: OK
1023 - 1: intrusion detected
1036 - 0: disable
1037 - 1: enable
1045 - 0, off, n: disable
1046 - 1, on, y: enable