Lines Matching +full:pulses +full:- +full:per +full:- +full:revolution
16 The contents of the label are free-form.
135 this voltage channel is being used for, and user-space
137 user-space.
145 When disabled the sensor read will return -ENODATA.
147 - 1: Enable
148 - 0: Disable
195 Unit: revolution/min (RPM)
203 Unit: revolution/min (RPM)
212 Unit: revolution/min (RPM)
230 Number of tachometer pulses per fan revolution.
241 the number of pulses. In the absence of such a register (and
242 thus attribute) the value assumed by all devices is 2 pulses
243 per fan revolution.
249 Unit: revolution/min (RPM)
253 Only makes sense if the chip supports closed-loop fan speed
263 this fan channel is being used for, and user-space doesn't.
264 In all other cases, the label is provided by user-space.
272 When disabled the sensor read will return -ENODATA.
274 - 1: Enable
275 - 0: Disable
283 - 1: Failed
284 - 0: Ok
302 - 0: no fan speed control (i.e. fan at full speed)
303 - 1: manual fan speed control enabled (using `pwmY`)
304 - 2+: automatic fan speed control enabled
313 - 0: DC mode (direct current)
314 - 1: PWM mode (pulse-width modulation)
343 Number of trip points is chip-dependent. Use this for chips
354 Number of trip points is chip-dependent. Use this for chips
367 - 1: CPU embedded diode
368 - 2: 3904 transistor
369 - 3: thermal diode
370 - 4: thermistor
371 - 5: AMD AMDSI
372 - 6: Intel PECI
388 - 0: OK
389 - 1: temperature has reached tempY_max
405 - 0: OK
406 - 1: temperature has reached tempY_min
452 - 0: OK
453 - 1: temperature has reached tempY_crit
482 - 0: OK
483 - 1: temperature has reached tempY_emergency
534 this temperature channel is being used for, and user-space
536 user-space.
572 When disabled the sensor read will return -ENODATA.
574 - 1: Enable
575 - 0: Disable
673 When disabled the sensor read will return -ENODATA.
675 - 1: Enable
676 - 0: Disable
869 -ENODATA.
871 - 1: Enable
872 - 0: Disable
905 -ENODATA.
907 - 1: Enable
908 - 0: Disable
916 - 0: OK
917 - 1: Humidity limit has been reached
926 -ENODATA.
928 - 1: Enable
929 - 0: Disable
937 - 1: Failed
938 - 0: Ok
946 Unit: milli-percent (per cent mille, pcm)
957 this humidity channel is being used for, and user-space
959 user-space.
967 Unit: milli-percent (per cent mille, pcm)
975 Unit: milli-percent (per cent mille, pcm)
986 Unit: milli-percent (per cent mille, pcm)
994 Unit: milli-percent (per cent mille, pcm)
1005 Unit: milli-percent (per cent mille, pcm)
1013 Unit: milli-percent (per cent mille, pcm)
1022 - 0: OK
1023 - 1: intrusion detected
1036 - 0: disable
1037 - 1: enable
1045 - 0, off, n: disable
1046 - 1, on, y: enable