Lines Matching full:units
152 unique to allow association with event codes. Units after
168 is required is a consistent labeling. Units after application
180 unique to allow association with event codes. Units after
189 unique to allow association with event codes. Units after
196 Raw capacitance measurement from channel Y. Units after
207 is required is a consistent labeling. Units after application
225 _raw units, this is the value that the zero point on the
243 less measurements. Units after application of scale and offset
260 Has all of the equivalent parameters as per voltageY. Units
280 Units after application of scale and offset are m/s^2.
294 Units after application of scale and offset are radians.
308 Units after application of scale and offset are meters per
316 Angle of rotation. Units after application of scale and offset
327 Units after application of scale and offset are milli percents
339 Units after application of scale and offset are radians per
395 Raw pressure measurement from channel Y. Units after
409 Raw humidity measurement of air. Units after application of
456 <type> units as specified in <type>[Y]_raw documentation.
516 measured value in <type> units as specified in
538 expressed in SI units (m/s^2 for accelerometers and rad/s
785 Set/get output current for channel Y. Units after application
992 value is in raw device units or in processed units (as _raw
1009 Specifies the conversion factor from the standard units
1010 to device specific units used to set the event trigger
1125 value is in raw device units or in processed units (as _raw
1256 Confidence value (in units as percentage) to be used
1513 expressed in units as percentage.
1539 user). Units after application of scale are Joules.
1548 activated. Units after application of scale are meters.
1569 to SI units is not possible. Higher proximity measurements
1570 indicate closer objects, and vice versa. Units after
1583 Illuminance measurement, units after application of scale
1657 Raw current measurement from channel X. Units are in milliamps
1693 Units after application of scale are m/s.
1861 Raw (unscaled no offset etc.) reading of a substance. Units
1872 Units after application of scale and offset are ohms.
1959 Units after application of scale and offset are siemens per
2017 Units after application of scale and offset are radians.
2070 Units after application of scale are nano nanowatts per square meter.
2089 is generated. Units are a percentage of the prior reading.
2158 Units and the exact meaning of value are device-specific.
2181 Lists all available tap reset timeout values. Units in seconds.
2195 tap. Units in seconds.
2203 Units in seconds.
2210 peak. Units in seconds.
2218 Raw (unscaled) euler angles readings. Units after