Lines Matching +full:spin +full:- +full:table
10 Addresses scanned: I2C 0x2c-0x2e
18 Addresses scanned: I2C 0x2c-0x2e
24 - Mark M. Hoffman <mhoffman@lightlink.com>
25 - Ported to 2.6 by Eric J. Bowersox <ericb@aspsys.com>
26 - Adapted to 2.6.20 by Carsten Emde <ce@osadl.org>
27 - Modified for mainline integration by Hans J. Koch <hjk@hansjkoch.de>
30 -----------------
33 Set to non-zero to force some initializations (default is 0).
38 Configures in7 and in8 limit type, where 0 means absolute and non-zero
54 --------------------
59 SMBus 2.0. Using an 8-bit ADC, the LM93 measures the temperature of two remote
63 table based. The LM93 includes a digital filter that can be invoked to smooth
77 --------------
88 exponential moving average (but not quite - check the datasheet). Note
90 from 0-255 where 0 indicates no throttling, and 255 indicates > 99.6%.
104 assert #P2_PROCHOT, and vice-versa. This mode is enabled by writing a
105 non-zero integer to the sysfs file prochot_short.
125 files are read-only.
129 If a fan is driven using a low-side drive PWM, the tachometer
144 are still some conditions that will override even this mode - see section
148 and pwm2 are used to set the manual duty cycle; each is an integer (0-255)
175 The eight control sources are: temp1-temp4 (aka "zones" in the datasheet),
192 function of the LM93 is derived from a base temperature and a table of 12
202 1 0 - 25.00%
203 2 0 - 28.57%
204 3 1 40C - 41C 32.14%
205 4 1 41C - 42C 35.71%
206 5 2 42C - 44C 39.29%
207 6 2 44C - 46C 42.86%
208 7 2 48C - 50C 46.43%
209 8 2 50C - 52C 50.00%
210 9 2 52C - 54C 53.57%
211 10 2 54C - 56C 57.14%
212 11 2 56C - 58C 71.43%
213 12 2 58C - 60C 85.71%
214 - - > 60C 100.00%
224 The LM93 can also apply hysteresis to the offset table, to prevent unwanted
225 oscillation between two steps in the offsets table. These values are found in
235 PWM Spin-Up Cycle
238 A spin-up cycle occurs when a PWM output is commanded from 0% duty cycle to
239 some value > 0%. The LM93 supports a minimum duty cycle during spin-up. These
242 duration of the spin-up cycle is also configurable. These values are found in
244 the spin-up time in seconds. The available spin-up times are constrained by
248 Spin-up Durations:
279 four tach input pins. GPIO0-GPIO3 correspond to (fan) tach 1-4, respectively.
285 -----------------------
301 pwm<n>_auto_spinup_min minimum duty cycle during spin-up
302 pwm<n>_auto_spinup_time duration of spin-up
306 temp<n>_auto_offset[1-12] temperature channel offsets
311 gpio input state of 8 GPIO pins; read-only