Lines Matching full:will

14   is the probability that a system will produce correct outputs.
99 will translate the error message to the silkscreen or component label for
232 CE events only, the system can and will continue to operate as no data
284 and one MC driver will be loaded. Both the CORE and the MC driver (or
347 controllers. The following example will assume 2 channels:
386 ranked DIMMs are placed in slots DIMM_A0 and DIMM_B0, then they will
387 have just one csrow (csrow0) and csrow1 will be empty. The pattern
394 ``/sys/devices/system/edac/mc``, each memory controller will be
503 this counter will not have a chance to increment, since EDAC
504 will panic the system.
517 This attribute file will display what type of DRAM device is
528 This attribute file will display what type of Error detection
560 This attribute file will display what type of memory is currently
579 When CONFIG_EDAC_LEGACY_SYSFS is enabled, sysfs will contain the ``csrowX``
592 this counter will not have a chance to increment, since EDAC
593 will panic the system.
614 This attribute file will display what type of memory is currently
624 This attribute file will display what type of Error detection
630 This attribute file will display what type of DRAM device is
642 This attribute file will display the count of CEs on this
648 This attribute file will display the count of UEs on this
671 This attribute file will display the count of CEs on this
678 This attribute file will display the count of UEs on this
700 If logging for UEs and CEs is enabled, then system logs will contain
736 Both UEs and CEs with no info will lack all but memory controller, error
775 This attribute file will display the number of parity errors that
784 An uncorrectable error will cause a machine panic. This is usually
787 system context might be so mangled that continuing will lead to further
788 corruption. If the kernel has MCE configured, then EDAC will never
805 will be accumulated even when UE logging is disabled.
821 CE statistics will be accumulated even when CE logging is disabled.
881 will appear.
970 reset-counters writing ANY thing to this control will
990 This chapter will cover the differences of the enhanced memory controllers
1022 The driver will map it as::
1045 channel = the channel that will generate an error;
1066 specifies what bits will have troubles,
1069 specifies what ECC cache section will get the error::
1087 Datasheet states that the error will only be generated after a write on an
1088 address that matches inject_addrmatch. It seems, however, that reading will
1091 For example, the following code will generate an error for any write access
1104 The generated error message will look like::
1130 dimm number will increment the same counter.
1138 The hardware will increment udimm0 for an error at the first dimm at either
1141 The hardware will increment udimm1 for an error at the second dimm at either
1144 The hardware will increment udimm2 for an error at the third dimm at either