Lines Matching full:count

1 What:		/sys/bus/counter/devices/counterX/countY/count
5 Count data of Count Y represented as a string.
11 Count value ceiling for Count Y. This is the upper limit for the
18 Count value floor for Count Y. This is the lower limit for the
25 Count mode for channel Y. The ceiling and floor values for
26 Count Y are used by the count mode where required. The following
27 count modes are available:
35 the Count Y ceiling value, while the lower limit is set
36 to the Count Y floor value. The counter freezes at
37 count = ceiling when counting up, and at count = floor
39 counting is resumed only when the count direction is
45 new count value is loaded to the counter via a preset
49 A count value boundary is set between the Count Y floor
50 value and the Count Y ceiling value. The counter is
51 reset to the Count Y floor value at count = ceiling when
52 counting up, while the counter is set to the Count Y
53 ceiling value at count = floor when counting down; the
64 Discrete set of available values for the respective Count Y
72 Read-only attribute that indicates the count direction of Count
73 Y. Two count directions are available: forward and backward.
79 This attribute exposes such count directions.
89 for Count Y. Suppose a counter device is used to count the total
106 Count function mode of Count Y; count function evaluation is
107 triggered by conditions specified by the Count Y signalZ_action
108 attributes. The following count functions are available:
111 Accumulated count is incremented.
114 Accumulated count is decremented.
117 Rising edges on signal A updates the respective count.
122 signal A updates the respective count; if the direction
124 updates the respective count. Quadrature encoding
129 signal B updates the respective count; if the direction
131 updates the respective count. Quadrature encoding
136 the respective count. Quadrature encoding determines the
141 the respective count. Quadrature encoding determines the
146 updates the respective count. Quadrature encoding
154 Count Y. If possible, this should match the name of the
162 used to load counter channels to a set count upon device-defined
163 preset operation trigger events -- the preset count for channel
177 Action mode of Count Y for Signal Z. This attribute indicates
178 the condition of Signal Z that triggers the count function
179 evaluation for Count Y. The following action modes are
183 Signal does not trigger the count function. In
184 Pulse-Direction count function mode, this Signal is