Lines Matching full:duty
167 Each PWM has 4 associated distinct output duty-cycles: full, high, low and
172 thermal thresholds exist that controls both PWMs output duty-cycles. The
179 PWM Auto Point PWM Output Duty-Cycle
181 pwm[1-2]_auto_point4_pwm full speed duty-cycle (hard-wired to 255)
182 pwm[1-2]_auto_point3_pwm high speed duty-cycle
183 pwm[1-2]_auto_point2_pwm low speed duty-cycle
184 pwm[1-2]_auto_point1_pwm off duty-cycle (hard-wired to 0)
194 PWM output duty-cycle based on the input temperature:
196 Thermal Threshold Output Duty-Cycle
199 full speed duty-cycle full speed duty-cycle
201 high speed duty-cycle full speed duty-cycle
203 low speed duty-cycle high speed duty-cycle
205 off duty-cycle low speed duty-cycle