Lines Matching full:this
7 state. This reports the regulator enable control, for
10 This will be one of the following strings:
26 NOTE: this field can be used in conjunction with microvolts
33 "status". This reports the current regulator status, for
36 This will be one of the following strings:
73 type. This holds the regulator type.
75 This will be one of the following strings:
97 microvolts. This holds the regulator output voltage setting
101 NOTE: This value should not be used to determine the regulator
102 output voltage level as this value is the same regardless of
112 microamps. This holds the regulator output current limit
116 NOTE: This value should not be used to determine the regulator
117 output current level as this value is the same regardless of
127 opmode. This holds the current regulator operating mode,
140 NOTE: This value should not be used to determine the regulator
141 output operating mode as this value is the same regardless of
152 min_microvolts. This holds the minimum safe working regulator
153 output voltage setting for this domain measured in microvolts,
156 NOTE: this will return the string 'constraint not defined' if
167 max_microvolts. This holds the maximum safe working regulator
168 output voltage setting for this domain measured in microvolts,
171 NOTE: this will return the string 'constraint not defined' if
182 min_microamps. This holds the minimum safe working regulator
183 output current limit setting for this domain measured in
186 NOTE: this will return the string 'constraint not defined' if
197 max_microamps. This holds the maximum safe working regulator
198 output current limit setting for this domain measured in
201 NOTE: this will return the string 'constraint not defined' if
212 name. This holds a string identifying the regulator for
215 NOTE: this will be empty if no suitable name is provided
225 num_users. This holds the number of consumer devices that
226 have called regulator_enable() on this regulator.
235 requested_microamps. This holds the total requested load
236 current in microamps for this regulator from all its consumer
246 This points to the parent or supply regulator if one exists.
254 suspend_mem_microvolts. This holds the regulator output
255 voltage setting for this domain measured in microvolts when
265 suspend_disk_microvolts. This holds the regulator output
266 voltage setting for this domain measured in microvolts when
276 suspend_standby_microvolts. This holds the regulator output
277 voltage setting for this domain measured in microvolts when
287 suspend_mem_mode. This holds the regulator operating mode
288 setting for this domain when the system is suspended to
298 suspend_disk_mode. This holds the regulator operating mode
299 setting for this domain when the system is suspended to disk,
309 suspend_standby_mode. This holds the regulator operating mode
310 setting for this domain when the system is suspended to
320 suspend_mem_state. This holds the regulator operating state
324 This will be one of the same strings reported by
333 suspend_disk_state. This holds the regulator operating state
337 This will be one of the same strings reported by
346 suspend_standby_state. This holds the regulator operating
350 This will be one of the same strings reported by